Research Article

A Comparative Study of Ground and Underground Vibrations Induced by Bench Blasting

Table 3

Vibration measurements taken on surface.

BlastBench, maximum charge by delay (kg), distance (m)PPV (mm/s)Frequency (Hz)

162835035104.915.3
350955.121.5

2628174352.930.5
1746551.333.5

36281743559.532.9
1746536.930.5

4628175357.036.0
1756538.725.0

562817410513.731.5

66281753569.334.2
1759564.332.3

7628175653.2 11.7
1751555.64.9

86281759723.816.5
1751263.112.2

96281443572.432.9
144654.031.7

106281323572.417.7
1326571.332.3
1329568.020.1

116281923572.417.7
1926543.123.8
1929530.732.3

126281323571.117.1
1326559.930.5
132954.931.7

136281443590.533.6
1446539.832.9
1449529.931.7

146281923592.538.4
1926538.132.2
192955.429.2

156281923521.718.3
1926570.552.5
1929271.850.7

166281683572.436.0
1686543.925.0