Research Article
Detection and Quantization of Bearing Fault in Direct Drive Wind Turbine via Comparative Analysis
Table 1
9 operation conditions and the fault feature frequencies.
| ā | (Hz) | (kW) | RPFI (Hz) | RPFO (Hz) | RSF (Hz) | FTF (Hz) |
| C1 | 0.133 | 0 | 3.432 | 3.101 | 1.315 | 0.070 | C2 | 0.15 | 40 | 3.861 | 3.489 | 1.479 | 0.079 | C3 | 0.17 | 60 | 4.376 | 3.954 | 1.676 | 0.089 | C4 | 0.25 | 205 | 6.435 | 5.815 | 2.466 | 0.131 | C5 | 0.262 | 125 | 6.735 | 6.087 | 2.581 | 0.137 | C6 | 0.267 | 300 | 6.864 | 6.203 | 2.630 | 0.140 | C7 | 0.273 | 200 | 7.035 | 6.358 | 2.696 | 0.143 | C8 | 0.283 | 345 | 7.293 | 6.590 | 2.794 | 0.149 | C9 | 0.283 | 485 | 7.293 | 6.590 | 2.794 | 0.149 |
|
|