A Method for Aileron Actuator Fault Diagnosis Based on PCA and PGC-SVM

Table 10

Fault analysis of aileron actuator.

ObjectFault modeFault causeFault phenomenon

Direct driving valveForce motor coil shutoffForce motor coil breakForce motor has no power output; the position of valve element is constantly in the neutral position.
BlockageOil pollutionNull bias increases; frequency response decreases; system is unstable.
Valve element stuckOil pollution
Slide valve distortion
The direct driving valve output constant flow; the system pressure decreases.
Valve leakageEdge abrasion
Radial valve element abrasion
Null bias increases; gain of system decreases; system pressure decreases; flow noise increases.
Null bias out-of-toleranceInaccurate zero setting Bias exists when DDV is at null position.

Displacement sensorCoil breakCable breakSensor has no output.
Constant biasIron core of sensor looseDisplacement bias.

Actuator cylinderExternal leakageSealing washers fail
Hydraulic leakage
The speed of moving parts decreases; system pressure decreases.
Internal leakage out-of- toleranceCylinder abrasion
Oil in high pressure area flow into low pressure area
The speed of moving parts decreases; system pressure decreases; vibration and noise appear.

Electronic amplifierGain reductionInternal faults of electronic amplifierMagnification notably decreases.