Research Article
A Method for Aileron Actuator Fault Diagnosis Based on PCA and PGC-SVM
Table 12
Fault injection details.
| Test number | Fault mode | Fault component | Changed parameter for fault injection (unit) | Parameter (normal) | Parameter (fault) |
| 1 | Force motor fault | Force motor | FMC gain | 1 | 0 |
| 2 | Sensor fault | Displacement sensor | Signal output (1/m) | 1 | 0 |
| 3 | Leakage fault | Actuator cylinder | Flow control valve equivalent orifice diameter (mm) | | 5 |
| 4 | Amplifier fault | Electronic amplifier | Gain | 50 | 15 |
|
|