Research Article

Multiple-Fault Detection Methodology Based on Vibration and Current Analysis Applied to Bearings in Induction Motors and Gearboxes on the Kinematic Chain

Table 4

Amplitude at the frequencies of interest for each gear condition without bearing defect and VFD set to 15 Hz.

ConditionAmplitude (×10−3 m/s2)

Healthy3.9792.0956.0501.1821.1441.305
25%15.967.4386.8211.3221.1781.363
50%37.7533.3128.461.3471.4051.347
75%42.2934.4830.091.4611.3221.345