Stator Vibration Characteristic Identification of Turbogenerator among Single and Composite Faults Composed of Static Air-Gap Eccentricity and Rotor Interturn Short Circuit
Table 3
Fault identification criterion based on stator vibration characteristics.
Stator vibration characteristics
Performing condition
Having only soft 2nd harmonic vibrations
Normal condition
The vibration at 2f is increased, while the other components generally keep stable
SAGE exists
The vibration at 2f is decreased, but meanwhile vibrations at f, 3f, and 4f are increased
RISC exists
The vibration at 2f is firstly decreased and then increased; meanwhile, vibrations at f, 3f, and 4f are increased