Research Article

Seismic Proofing Capability of the Accumulated Semiactive Hydraulic Damper as an Active Interaction Control Device with Predictive Control

Table 2

The maximum structural response of test structure under excitation of El Centro earthquake record with various control conditions and different peak ground acceleration.

Number of stiffeners at 1st floorNumber of stiffeners at 2nd floorControl conditionsA0 
m/sec2
D1 
mm
D2 
mm
A1 
m/sec2
A2 
m/sec2
Base shear 
kN

00NC0.44525.816.81.0571.3538.2
22Passive0.42317.59.91.3931.70112.4
22Passive0.90833.418.13.1493.12125.4
43Passive0.43914.010.71.6162.40815.8
43Passive0.79525.718.83.0004.17829.7
22Synchronic and 0.13-second predictive control2.15929.723.02.9413.96724.5
22Synchronic and 0.13-second predictive control1.75823.717.72.6323.34924.1
22Synchronic and 0.13-second predictive control1.33517.612.71.7912.40115.3
22Synchronic and 0.13-second predictive control0.95712.08.11.8071.70813.6
22Synchronic and 0.13-second predictive control0.4747.45.31.2281.0458.6
22Synchronic and 0.10-second predictive control2.18931.024.13.0954.41325.7
22Synchronic and 0.10-second predictive control2.11923.517.82.1803.33621.3
22Synchronic and 0.10-second predictive control1.50317.312.71.6692.51214.5
22Synchronic and 0.10-second predictive control0.87011.48.11.0631.8019.9
22Synchronic and 0.10-second predictive control0.4767.55.20.8061.0988.3
22Synchronic and 0.07-second predictive control1.22224.419.22.2493.48520.5
22Synchronic and 0.07-second predictive control0.88118.114.01.5152.36414.3
22Synchronic and 0.07-second predictive control0.42210.17.20.9271.2217.9
22Synchronic control1.40625.920.52.3013.67721.0
22Synchronic control0.92818.514.11.5052.39214.2
22Synchronic control0.42311.07.30.9031.2678.1
22Asynchronic and 0.10-second predictive control1.64631.426.76.1124.65328.7
22Asynchronic and 0.10-second predictive control1.47321.419.64.1993.44519.1
22Asynchronic and 0.10-second predictive control0.85517.814.22.7492.62911.5
22Asynchronic and 0.10-second predictive control0.4569.08.31.6631.4437.0
220.10-second predictive control at 1st floor1.64230.030.76.7825.90829.0
220.10-second predictive control at 1st floor1.25922.122.84.9284.23820.9
220.10-second predictive control at 1st floor0.97116.415.73.2502.76713.1
220.10-second predictive control at 1st floor0.4378.88.41.7741.5477.7
220.10-second predictive control at 2nd floor0.85124.220.93.7273.79820.9
220.10-second predictive control at 2nd floor0.46512.811.21.7591.90211.1
43Synchronic and 0.10-second predictive control2.60726.623.34.6746.53637.1
43Synchronic and 0.10-second predictive control2.37421.920.34.1165.33635.3
43Synchronic and 0.10-second predictive control1.93418.517.33.6194.85326.1
43Synchronic and 0.10-second predictive control1.29514.813.52.9133.40622.3
43Synchronic and 0.10-second predictive control0.91410.110.01.7882.37814.7
43Synchronic and 0.10-second predictive control0.4356.54.10.8831.3799.4