Research Article

A Shock Mitigation of Pedestrian-Vehicle Impact Using Active Hood Lift System: Deploying Time Investigation

Table 1

Material properties of AHLS.

SymbolValueSpecification

4.4 × 10−5 m4Inertia moment of bracket release
8.3 × 10−5 m4Inertia moment of pop-up guide
5.1 × 10−5 m4Inertia moment of emergency pawl
9.8 × 10−4 m4Inertia moment of pop-up guide and pin striker, which rotate together after point (B)
1 Nm/radSpring coefficient of spring installed at bracket release
1 Nm/radSpring coefficient of spring installed at pop-up guide
3 Nm/radSpring coefficient of spring installed at emergency pawl
0.16Coefficient of rolling friction
0.3Friction coefficient
6.67 kgMass of hood that is lifted at latch part