Research Article

Flap/Lag Stall Flutter Control of Large-Scale Wind Turbine Blade Based on Robust H2 Controller

Table 2

The values of and 1st frequencies (Hz) versus ply angles (°).

Ply angles1st frequency

00.007012.815
150.013527.106
300.054478.005
450.083998.366
600.072766.442
750.052332.636
900.043320.531