Research Article

A Comparison of Vibroacoustic Response of Isotropic Plate with Attached Discrete Patches and Point Masses Having Different Thickness Variation with Different Taper Ratios

Table 6

Comparison of natural frequency variation of plate with attached four point masses with different taper ratio ().

CaseModeNatural frequency
= 0 = 0.3 = 0.6 = 0.9

II83.55883.09681.57971.519
II174.55169.98161.80139.18
III224.63219.30196.24152.52
IV281.54272.39267.29255.22

III83.55882.2780.30172.754
II174.55170.66167.22159.54
III224.63217.61200.72165.97
IV281.54274.27270.98262.24

IIII83.55883.45582.4279.912
II174.55171.38170.42150.89
III224.63219.32205.04194.90
IV281.54272.21261.36254.90

IVI83.55883.09182.91381.649
II174.55167.05162.18158.97
III224.63218.05204.16185.41
IV281.54276.36268.62259.12