Research Article

Wind-Induced Coupling Vibration Effects of High-Voltage Transmission Tower-Line Systems

Table 6

Comparison of vibration characteristics from the finite element analysis and field measurements.

Measurement locationVibration frequency (Hz)Damping ratio (%)
Finite element calculation ()Field measurement ()Deviation
)
Finite element calculation ()Field measurement ()Deviation
()

A1.981.970.51%1.181.54−23.4%
B5.935.625.52%2.616.28−58.4%
C6.476.224.02%1.303.00−56.7%
D5.415.410.00%1.952.90−32.8%