Research Article

A Hybrid Lumped Parameters/Finite Element/Boundary Element Model to Predict the Vibroacoustic Characteristics of an Axial Piston Pump

Table 3

Details description of the components in the hydraulics system.

NumberDescriptionDetail

1Inlet pressure sensorNS-I1, 0–10 bar, accuracy 0.3% FS
2Inlet temperature sensorSBWR/Z, range −25–120°C, accuracy 0.25% FS
3Electric motorY315L2-2, speed range 300–298 rpm
4Shaft speed sensorJC2C, range 0–4000 rpm, accuracy ±1 rpm
5Shaft torque sensorJC2C, range 0–2000 Nm, 0.2 class accuracy
6Outlet pressure sensorNSI1, range 0–400 bar, accuracy 0.3% FS
7Outlet flow meterLC-A50, range 0–400 L/min, 0.2 class accuracy
8Pressure relief valveDBDH6P1X400
9Test pumpDisplacement 71 cm3/r