Research Article

Wind Induced Vibration Control and Energy Harvesting of Electromagnetic Resonant Shunt Tuned Mass-Damper-Inerter for Building Structures

Table 1

The parameters of simulation.

DescriptionSymbolValue

Primary structure mass8.46 107 [kg]
Mechanical TMD mass6.60 105 [kg]
Inertance mass3.30 105 [kg]
Stiffness of the primary structure7.12 107 [N/m]
Stiffness of the mechanical TMD8.21 105 [N/m]
Total inductance of electrical resonator1.17 [H]
Total capacitance of electrical resonator1.02 [F]
Internal resistance of linear motor0.1 []
External resistance0.1 []
The constant of the electromagnetic transducer, 150