Research Article

Deep Learning Enabled Fault Diagnosis Using Time-Frequency Image Analysis of Rolling Element Bearings

Table 21

Confusion matrix for CWR (a) 96 96 and (b) 32 32 scalograms for the proposed architecture.
(a)

ā€‰NBFIROR

N98.4%0.6%0.0%1.0%
BF0.0%99.8%0.0%0.2%
IR0.0%0.0%100%0.0%
OR0.2%0.0%0.0%99.7%

(b)

ā€‰NBFIROR

N97.0%2.0%0.0%1.0%
BF0.5%99.1%0.0%0.3%
IR0.0%0.0%100%0.0%
OR0.6%0.6%0.0%98.8%