Research Article
Enhanced Bearing Fault Detection Using Step-Varying Vibrational Resonance Based on Duffing Oscillator Nonlinear System
Figure 9
Analysis results for the bearing signal with a defective inner race: (a) original signal; (b) envelope signal with a filtering band at 2500–3000 Hz; (c) optimal MSTSR output signal (optimal parameters: , , , and ); (d) optimal WSSR output signal (optimal parameters: , , , and ); (e) optimal WSGSR output signal (optimal parameters: , , , V1 = 0.8, , and ); and (f) optimal SVVR output signal (optimal parameters: , , , , , and rad/s).
(a) |
(b) |
(c) |
(d) |
(e) |
(f) |