Research Article

Experimental Study on Variation Rules of Damping with Influential Factors of Tuned Liquid Column Damper

Table 1

Experimental scheme and measured data.

Experiment numberTotal length of liquid columnOpening ratioReynolds numberKc numberLength of horizontal liquid columnVelocity of vertical liquid column
V (mm/s)
Motor speed (r/min)Head loss coefficient

N119.50.69615.388.513.67238.37326.7
N2190.710538.57.913.67241.8832.44.73
N3200.510307.76.712.33279.8752.328.53
N4180.59615.387.313.00261.0744.8225
N5180.610076.97.912.33249.8136.188.6
N6180.410538.56.111.67320.0973.5640.8
N7190.310076.96.713.00353.1085.2373.9
N817.50.810538.55.512.33226.2240.752.86
N9190.49846.157.911.67299.0753.0742.5
N10200.410538.57.913.00320.0956.840.07
N11180.610769.26.713.67266.9745.597.57
N1218.50.49846.155.513.67299.0776.2337.75
N1318.50.89615.386.711.67206.4130.523.14
N14200.810076.96.113.67216.3135.133.83
N1519.50.710769.27.311.67247.1835.875.07
N1618.50.310769.28.512.33377.3671.7973.2
N17200.79846.157.312.33225.9932.85.87
N1817.50.310307.77.313.67361.1980.0262.1
N1919.50.510769.25.513.00292.4066.6228.7
N2017.50.79846.156.113.00225.9939.244.95
N21190.610307.75.511.67255.5353.166.07
N2217.50.510076.98.511.67273.6040.3422.3
N2317.50.89615.385.511.67206.4031.362.2

Diameter of circular orificeOpening ratio of orifice = 0.3Opening ratio of orifice = 0.4Opening ratio of orifice = 0.5Opening ratio of orifice = 0.6Opening ratio of orifice = 0.7Opening ratio of orifice = 0.8
37.1 mm37.1 mm47.88 mm52.44 mm56.64 mm60.56 mm

TLCD modelOriginal total lengthOriginal horizontal lengthSide length of cross section
140 cm60 cm6 cm