Table of Contents Author Guidelines Submit a Manuscript
Shock and Vibration
Volume 2017, Article ID 7350369, 11 pages
https://doi.org/10.1155/2017/7350369
Research Article

Characteristics of Rainfall in Wind Field of a Downburst and Its Effects on Motion of High-Voltage Transmission Line

Chao Zhou,1,2 Li Li,1 and Yibing Liu1,2

1School of Energy Power and Mechanical Engineering, North China Electric Power University, Beijing 102206, China
2Key Laboratory of Condition Monitoring and Control for Power Plant Equipment Ministry of Education, North China Electric Power University, Beijing 102206, China

Correspondence should be addressed to Chao Zhou; nc.ude.upecn@oahcuohz

Received 1 September 2016; Revised 14 November 2016; Accepted 20 December 2016; Published 23 January 2017

Academic Editor: Aly Mousaad Aly

Copyright © 2017 Chao Zhou et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. T. T. Fujita, The Downburst: Microburst and Macroburst, Report of Projects NIMROD and JAWS, University of Chicago, 1985.
  2. A. Y. Shehata and A. A. El Damatty, “Behaviour of guyed transmission line structures under downburst wind loading,” Wind and Structures, vol. 10, no. 3, pp. 249–268, 2007. View at Publisher · View at Google Scholar · View at Scopus
  3. D. Dempsey and H. B. White, “Winds wreak havoc on lines,” Transmission and Distribution World, vol. 48, no. 6, pp. 32–42, 1996. View at Google Scholar
  4. E. Savory, G. A. R. Parke, M. Zeinoddini, N. Toy, and P. Disney, “Modelling of tornado and microburst-induced wind loading and failure of a lattice transmission tower,” Engineering Structures, vol. 23, no. 4, pp. 365–375, 2001. View at Publisher · View at Google Scholar · View at Scopus
  5. A. Y. Shehata, A. A. El Damatty, and E. Savory, “Finite element modeling of transmission line under downburst wind loading,” Finite Elements in Analysis and Design, vol. 42, no. 1, pp. 71–89, 2005. View at Publisher · View at Google Scholar · View at Scopus
  6. H. Aboshosha and A. E. Damatty, “Effective technique to analyze transmission line conductors under high intensity winds,” Wind and Structures, vol. 18, no. 3, pp. 235–252, 2014. View at Publisher · View at Google Scholar · View at Scopus
  7. S. Liang, L. Zou, D. Wang, and H. Cao, “Investigation on wind tunnel tests of a full aeroelastic model of electrical transmission tower-line system,” Engineering Structures, vol. 85, pp. 63–72, 2015. View at Publisher · View at Google Scholar · View at Scopus
  8. Y. Eguchi, N. Kikuchi, K. Kawabata, T. Yukino, and Y. Ishikubo, “Drag reduction mechanism and aerodynamic characteristics of a newly developed overhead electric wire,” Journal of Wind Engineering and Industrial Aerodynamics, vol. 90, no. 4-5, pp. 293–304, 2002. View at Publisher · View at Google Scholar · View at Scopus
  9. N. Kikuchi, Y. Matsuzaki, T. Yukino, and H. Ishida, “Aerodynamic drag of new-design electric power wire in a heavy rainfall and wind,” Journal of Wind Engineering and Industrial Aerodynamics, vol. 91, no. 1-2, pp. 41–51, 2003. View at Publisher · View at Google Scholar · View at Scopus
  10. H.-N. Li, S.-Y. Tang, and T.-H. Yi, “Wind-rain-induced vibration test and analytical method of high-voltage transmission tower,” Structural Engineering and Mechanics, vol. 48, no. 4, pp. 435–453, 2013. View at Publisher · View at Google Scholar · View at Scopus
  11. X. Fu, H.-N. Li, and Y. B. Yang, “Calculation of rain load based on single raindrop impinging experiment and applications,” Journal of Wind Engineering and Industrial Aerodynamics, vol. 147, pp. 85–94, 2015. View at Publisher · View at Google Scholar · View at Scopus
  12. Y. Wei, Q. Yang, X. Xiong, J. Wang, and S. Weng, “Short-term reliability evaluation of transmission system under strong wind and rain,” Journal of Power and Energy Engineering, vol. 2, no. 4, pp. 665–672, 2014. View at Publisher · View at Google Scholar
  13. C. Zhou, Y.-P. Liu, and Y.-W. Song, “Mechanism and modeling of rain-wind induced in-plane vibration on high-voltage transmission line,” Journal of Mechanical Science and Technology, vol. 28, no. 4, pp. 1175–1180, 2014. View at Publisher · View at Google Scholar · View at Scopus
  14. C. Zhou, Y. B. Liu, and X. M. Rui, “Mechanism and characteristic of rain-induced vibration on high-voltage transmission line,” Journal of Mechanical Science and Technology, vol. 26, no. 8, pp. 2505–2510, 2012. View at Publisher · View at Google Scholar · View at Scopus
  15. M. R. Hjelmfelt, “Structure and life cycle of microburst outflows observed in Colorado,” Journal of Applied Meteorology, vol. 27, no. 8, pp. 900–927, 1988. View at Publisher · View at Google Scholar · View at Scopus
  16. L. Chen and C. W. Letchford, “A deterministic-stochastic hybrid model of downbursts and its impact on a cantilevered structure,” Engineering Structures, vol. 26, no. 5, pp. 619–629, 2004. View at Publisher · View at Google Scholar · View at Scopus
  17. J. D. Holmes and S. E. Oliver, “An empirical model of a downburst,” Engineering Structures, vol. 22, no. 9, pp. 1167–1172, 2000. View at Publisher · View at Google Scholar · View at Scopus
  18. E. C. C. Choi, “Numerical modelling of gust effect on wind-driven rain,” Journal of Wind Engineering and Industrial Aerodynamics, vol. 72, no. 1-3, pp. 107–116, 1997. View at Publisher · View at Google Scholar · View at Scopus
  19. Y. Mualem and S. Assouline, “Mathematical model for rain drop distribution and rainfall kinetic energy,” Transactions of the American Society of Agricultural Engineers, vol. 29, no. 2, pp. 494–500, 1986. View at Publisher · View at Google Scholar · View at Scopus
  20. J. S. Marshall and W. M. Palmer, “The distribution of raindrops with size,” Journal of Meteorology, vol. 5, no. 4, pp. 165–166, 1948. View at Publisher · View at Google Scholar
  21. H. Yamaguchi, “Analytical study on growth mechanism of rain vibration of cables,” Journal of Wind Engineering and Industrial Aerodynamics, vol. 33, no. 1-2, pp. 73–80, 1990. View at Publisher · View at Google Scholar · View at Scopus
  22. A. Bosdogianni and D. Olivari, “Wind-and rain-induced oscillations of cables of stayed bridges,” Journal of Wind Engineering and Industrial Aerodynamics, vol. 64, no. 2-3, pp. 171–185, 1996. View at Publisher · View at Google Scholar · View at Scopus
  23. M. Gu and L. Huang, “Theoretical and experimental studies on the aerodynamic instability of a two-dimensional circular cylinder with a moving attachment,” Journal of Fluids and Structures, vol. 24, no. 2, pp. 200–211, 2008. View at Publisher · View at Google Scholar · View at Scopus
  24. E. Simiu and R. H. Scanlan, Wind Effects on Structures: Fundaments and Applications to Design, John Wiley & Sons, New York, NY, USA, 1996.
  25. C. Zhou and Y. Liu, “Analytical model of rain-wind induced vibration of high-voltage transmission line,” Advances in Mechanical Engineering, vol. 2014, Article ID 638653, 9 pages, 2014. View at Publisher · View at Google Scholar · View at Scopus
  26. Q. Xie, Y. Zhang, and J. Li, “Investigation on tower collapses of 500 kV Renshang 5237 transmission line caused by downburst,” Power System Technology, vol. 30, no. 10, pp. 59–64, 2006. View at Google Scholar