Research Article

Vibration Analysis for Monitoring of Ancient Tie-Rods

Table 2

Summary of results.

Tie-rod numberAxial load [kN]Stress [MPa]Bed stiffness [107 MN/m2]Residual error

PT129.4062.8250.000.31
PT246.90102.180.486.04
PT337.5072.12253.003.95
PT438.7075.883.750.77
PT51.001.8926.751.17
PT666.5066.50113.000.48
PT754.5054.5057.501.43
PT846.3046.3060.006.60
PT944.5044.5062.507.33
PT1079.9079.9076.002.22
PT1130.1050.1799.506.53
PT1237.2062.004.250.48
PT1328.2047.005.500.27
PT1438.0063.332.135.58