Research Article
Vibration Analysis for Monitoring of Ancient Tie-Rods
Table 2
Summary of results.
| Tie-rod number | Axial load [kN] | Stress [MPa] | Bed stiffness [107 MN/m2] | Residual error |
| PT1 | 29.40 | 62.82 | 50.00 | 0.31 | PT2 | 46.90 | 102.18 | 0.48 | 6.04 | PT3 | 37.50 | 72.12 | 253.00 | 3.95 | PT4 | 38.70 | 75.88 | 3.75 | 0.77 | PT5 | 1.00 | 1.89 | 26.75 | 1.17 | PT6 | 66.50 | 66.50 | 113.00 | 0.48 | PT7 | 54.50 | 54.50 | 57.50 | 1.43 | PT8 | 46.30 | 46.30 | 60.00 | 6.60 | PT9 | 44.50 | 44.50 | 62.50 | 7.33 | PT10 | 79.90 | 79.90 | 76.00 | 2.22 | PT11 | 30.10 | 50.17 | 99.50 | 6.53 | PT12 | 37.20 | 62.00 | 4.25 | 0.48 | PT13 | 28.20 | 47.00 | 5.50 | 0.27 | PT14 | 38.00 | 63.33 | 2.13 | 5.58 |
|
|