Numerical simulation cases.

CasePurpose of analysesDepth, (m)Width, (m)Distance, (m)Type of isolation trench

1Trench width180.5, 1, 29Open trench
2Trench depth6, 12, 1829Open trench
3Trench position1825, 9, 13Open trench