Research Article
A Study on Internal Explosion Testing of the “Rigid-Flexible-Rigid” Three-Layer Sealed Structure
Table 9
The contact pressure peak between two adjacent layers (
).
| Measurement points | Explosive charge quantity/ (kg) | 0.15 | 0.2 | 0.3 | 0.475 | 0.8 |
| P-A-2 | | Model 1 | 56.15 | 95.25 | 138.26 | 220.99 | 744.05 | Model 2 | 68.42 | 188.26 | 281.42 | 433.88 | 1276.26 | P-A-3 | | Model 1 | 22.06 | 46.93 | 52.74 | 106.08 | 400.26 | Model 2 | 46.52 | 67.46 | 91.78 | 164.27 | 522.49 | P-B-2 | | Model 1 | 22.04 | 31.28 | 36.95 | 49.22 | 185.45 | Model 2 | 40.13 | 64.56 | 80.42 | 104.66 | 334.33 | P-B-3 | | Model 1 | 15.45 | 17.68 | 24.31 | 24.94 | 120.06 | Model 2 | 16.98 | 26.44 | 36.01 | 52.88 | 162.70 | P-C-2 | | Model 1 | / | 12.81 | 15.56 | 17.02 | 67.57 | Model 2 | 12.88 | 16.72 | 34.33 | 43.39 | 138.24 | P-C-3 | | Model 1 | / | / | 8.23 | 8.42 | 50.95 | Model 2 | 12.45 | 15.14 | 20.08 | 25.02 | 121.49 |
|
|