Research Article

A Study on Internal Explosion Testing of the “Rigid-Flexible-Rigid” Three-Layer Sealed Structure

Table 9

The contact pressure peak between two adjacent layers ().

Measurement pointsExplosive charge quantity/ (kg)
0.150.20.30.4750.8

P-A-2
Model 156.1595.25138.26220.99744.05
Model 268.42188.26281.42433.881276.26
P-A-3
Model 122.0646.9352.74106.08400.26
Model 246.5267.4691.78164.27522.49
P-B-2
Model 122.0431.2836.9549.22185.45
Model 240.1364.5680.42104.66334.33
P-B-3
Model 115.4517.6824.3124.94120.06
Model 216.9826.4436.0152.88162.70
P-C-2
Model 1/12.8115.5617.0267.57
Model 212.8816.7234.3343.39138.24
P-C-3
Model 1//8.238.4250.95
Model 212.4515.1420.0825.02121.49