Research Article
Dynamic Response of a 100,000 m3 Cylindrical Oil-Storage Tank under Seismic Excitations: Experimental Tests and Numerical Simulations
Table 2
Peak accelerations of input waves in X, Y, and Z directions.
| Input wave | Peak accelerations (g) | Seismic precautionary intensity | X | Y | Z |
| 1-1 | 0.034 | 0.145 | 0.014 | 6 | 1-2 | 0.096 | 0.173 | 0.026 | 7 | 1-3 | 0.123 | 0.306 | 0.075 | 8 | 2-1 | 0.130 | 0.304 | 0.161 | 8 | 2-2 | 0.137 | 0.444 | 0.138 | 9 | 2-3 | 0.290 | 0.504 | 0.298 | 10 or above | 2-4 | 0.324 | 0.653 | 0.439 | 10 or above |
|
|