Research Article
Research on an Ultrasonic Cutting Device Based on 0Cr18Ni9
Table 1
Comparative results of analysis and measurements.
| ā | Analytic value | Optimized value | Measured value | Analytical error (%) | Optimization analysis error (%) |
| Resonant frequency (kHz) | 30 | 30.542 | 29.650 | 1.2 | 3 | Amplification factor (Mp) | 2.78 | 2.39 | 2.03 | 36.9 | 17.7 |
|
|