Research Article

Experimental Investigation of Pressure Fluctuation, Vibration, and Noise in a Multistage Pump

Table 1

Main structural parameters.

Main geometric parametersValue

Inlet diameter of inlet section /mm100
Impeller outer diameter /mm314
The number of first-stage impeller blades 6
The outlet width of first-stage impeller /mm20.5
The number of second-stage impeller blades 7
The outlet width of second-stage impeller /mm20.5
Inlet diameter of guide vane /mm316
Outer diameter of guide vane /mm409
Blade number of positive guide vane 9
Blade number of negative guide vane 10
Outlet diameter of outlet section /mm80