Research Article
Seismic Protection of Cabinet Stored Cultural Relics with Silicone Dampers
Table 7
Force and displacement of each damper in layout A (experimental).
| Input levels | 1# damper | 2# damper | 3# damper | 1# damper | 2# damper | 3# damper | Force/kN | Force/kN | Force/kN | Displacement/mm | Displacement/mm | Displacement/mm |
| T01 (0.20 g) | 0.32 | 0.09 | 0.13 | 0.07 | / | 0.15 | T02 (0.20 g) | 0.34 | 0.06 | 0.08 | 0.07 | / | 0.04 | T03 (0.20 g) | 0.28 | 0.11 | 0.13 | 0.06 | / | 0.15 |
| T04 (0.40 g) | 0.85 | 0.20 | 0.41 | 0.17 | / | 0.34 | T05 (0.40 g) | 0.96 | 0.18 | 0.13 | 0.32 | / | 0.14 | T06 (0.40 g) | 0.58 | 0.22 | 0.26 | 0.24 | / | 0.23 |
| T07 (0.20 g) | 2.23 | 0.99 | 1.09 | 1.61 | / | 0.60 | T08 (0.62 g) | 2.39 | 0.74 | 1.04 | 2.69 | / | 0.99 | T09 (0.62 g) | 0.81 | 0.61 | 0.32 | 0.38 | / | 1.27 |
|
|
Note. The data missing of 2# damper’s displacement is due to the damage of measuring instrument during the test.
|