Research Article

An Experimental Test Bed for Developing High-Rate Structural Health Monitoring Methods

Table 1

Finite element and experimental natural frequencies for the DROPBEAR with no added mass ( = 0 kg), adding the electromagnet near the beam tip ( = 0.259 kg), and with the electromagnet and added mass plates ( = 0.695 kg). Percent errors are relative to the experimentally obtained natural frequencies.

Added Mass () ModeExperimentalFinite Element
Natural Frequency [Hz]Natural Frequency [Hz]Error

0 kg119.619.8
2124.5123.8
3350.0346.8

0.259 kg115.315.2
2106.9106.6
3311.8307.2

0.695 kg111.611.6
291.590.6
3240.8233.3