Finite element and experimental natural frequencies for the DROPBEAR with the rollers at distances from the clamped end () of 46 mm, 147 mm, and 246 mm. Percent errors are relative to the experimentally obtained natural frequencies.

Cart Position () Mode Experimental Finite Element
Natural Frequency [Hz] Natural Frequency [Hz] Error

46 mm 1 22.9 22.8
2 144.8 143.4
3 404.0402.7

147 mm1 33.2 33.7
2 218.6 217.7
3 645.2 615.6

246 mm 1 55.6 56.6
2 352.1 355.2
3 550.2 503.5