Research Article

Unbalanced Vibration Identification of Tangential Threshing Cylinder Induced by Rice Threshing Process

Table 1

Performance parameters of vibration test instruments.

Equipment name Performance indexParameter valuesManufacturer

Three-direction acceleration sensor of 356A16Sensitivity100 mV/gAmerican voltage Company (PCB)
Frequency response0.3~6 KHz
Range±50 g pk
Lateral sensitivity<5%

Dynamic signal acquisition instrument of DH5902Channel32Chinese Donghua testing company
Sampling bandwidth16, 100 KHz
End scale value±20 mv~±20 V
Distortion factor<0.5%