Research Article
Seismic Capacity Assessment of Confined Brick Masonry Building: An Experimental Approach
| Symbol | Description | Value |
| - | Water absorption of bricks (%) | 24.37 | | Masonry unit compressive strength (MPa) | 14.40 | | Modulus of rupture (MPa) | 3.38 | | Compressive strength of mortar (MPa) | 5.63 | | Compressive strength of masonry (MPa) | 3.51 | | Elastic modulus of masonry (MPa) | 1227.0 | | Diagonal tensile strength of masonry (MPa) | 0.046 | | Cohesion | 2.73 |
|
|