Research Article
Structural Damage Identification Based on the Transmissibility Function and Support Vector Machine
Table 7
Detection accuracy of identified damage locations based on PC and SVM.
| Damage location (floor) | Accuracy | Without noise | With 5% noise | With 10% noise |
| 5 | 100% (16/16) | 93.75% (15/16) | 87.50% (15/16) | 4 | 100% (16/16) | 93.75% (15/16) | 87.50% (15/16) | 3 | 100% (16/16) | 93.75% (15/16) | 81.25% (13/16) | 2 | 87.50% (14/16) | 87.50% (14/16) | 81.25% (13/16) |
|
|