Abstract

This paper deals with the seismic retrofit of existing frames by means of external passive dissipative systems. Available in different configurations, these systems allow high flexibility in controlling the structural behaviour and are characterized by some feasibility advantages with respect to dissipative devices installed within existing frames. In particular, this study analyzes and compares the performances of two external solutions using linear viscous dampers. The first is based on the coupling of the building with an external fixed-based steel braced frame by means of dampers placed horizontally at the floor levels. The second is an innovative one, based on coupling the building with a “dissipative tower,” which is a steel braced frame hinged at the foundation level, and activating the dampers through its rocking motion. The effectiveness of the two solutions is evaluated and compared by considering a benchmark existing reinforced concrete building, employing a stochastic dynamic approach, under the assumption of linear elastic behaviour for the seismic performance evaluation. This allows efficiently estimating the statistics of many response parameters of interest for the performance assessment and thus carrying out extensive parametric analyses for different properties of the external systems. The study results provide useful information regarding the design and the relative efficiency of the proposed retrofit solutions.

1. Introduction

Traditional approaches for the seismic performance enhancement and retrofit of buildings by means of passive damping usually involve installing the dissipative devices within the building frame in either diagonal or chevron braces connecting adjacent storeys [1, 2]. This type of damping configuration has been extensively studied in the last decades both experimentally and numerically, with a significant number of works focusing on design criteria and performance assessment [311]. However, the use of dampers within building frames presents some disadvantages, especially when employed for the retrofit of existing buildings. The increase of internal actions in the nodes and columns adjacent to the dampers can induce premature local failures [10], strengthening the foundations is generally required, retrofitting operations cause remarkable downtime, and relevant costs must be sustained. For these reasons, there is an increasing interest on external passive control systems, characterized by minimized interferences with the existing frame, during the installation of the retrofit system and also during the building operation. External damping systems are available in different configurations [1113], allowing high flexibility in controlling the structural behaviour, but their relative efficiency in terms of seismic performance has not been fully investigated to date. In fact, most of the studies in the literature focus on the most recurrent configuration involving the coupling of the structure to be protected with an external one by means of dampers placed horizontally at the storey level (Figure 1(a)). The external structure can be stiff, or it can be flexible, as in the case of adjacent buildings with different dynamic properties [1418]. The dampers are activated by the absolute floor displacements in the first case and by the relative floor motion of the systems in the latter one. It is noteworthy that the first configuration can also be designed to achieve mass proportional damping, where the viscous damping constants are proportional to the floor masses [12].

Recently, an innovative external retrofit configuration, denoted as “dissipative tower,” has been proposed. This consists of an external stiff braced structure rigidly linked to the frame at floor levels and connected at the foundations by a hinge (Figure 1(b)). Fluid viscous dampers (FVDs) placed at the base of the external frame and activated by its rocking motion provide energy dissipation to the system, whereas the high stiffness of the braced frame induces a uniform distribution of the interstorey drifts of the protected frame [19].

It is noteworthy that the use of rocking systems has emerged in the last few years as an efficient way to reduce seismic damage [20] and different solutions are available for coupling the frame and the external pinned rocking structures [21, 22]. The rocking tower considered in this study has been employed for the seismic design of new constructions and for retrofitting existing buildings [23, 24] by using a patented technical solution [25]. However, its effectiveness has not been compared yet to the one of more diffused systems involving the coupling between two structures by means of viscous dampers placed horizontally at the floor level.

In this paper, a performance comparison between the two retrofit configurations, that is, the fixed base structure with horizontal FVDs and the rocking tower with vertical FVDs at the base, is carried out through a parametric analysis involving a reference existing building, widely studied in the past [2628]. The performance comparison is made first in terms of dynamic properties, that is, vibration periods and damping ratios, and then in terms of seismic response of different engineering demand parameters (EDPs) of interest for the safety assessment of the building, the external bracings, and the dampers. In the analyses, the system behaviour is assumed as linear, and the earthquake input is modelled as a stationary stochastic process. Under these assumptions, the problem can be analyzed in the frequency-domain and already available stochastic dynamics techniques [29, 30] can be efficiently used to obtain closed-form expressions of the seismic response statistics, expressed in terms of standard deviation and peak values of the EDPs of interest for a finite time of observation. This approach allows investigating and comparing a wide range of configurations, corresponding to different levels of stiffness and damping of the external systems. The study results give useful information regarding the design of the external configurations and their relative efficiency for retrofitting existing buildings. It is noteworthy that the elastic behaviour assumption for the problem at hand is reasonable since for practical design applications linear FVDs are often designed in external retrofit systems in such a way as to enhance the performance levels for the building avoiding damages to the structural building components (e.g., immediate occupancy or operational performance level, corresponding to negligible structural damage).

2. Problem Formulation

The reported formulation is suitable for both the two external arrangements; under the assumption of linear elastic behaviour, the equation of motion of the system can be expressed in general aswhere is the vector of nodal displacements and rotations; the dot (·) denotes time-derivative; is the load distribution vector; denotes the total number of degrees of freedom; and is the external scalar loading function describing the seismic base acceleration. The time constant matrices M, K, and C describe the mass, stiffness, and damping operators ; they account for the contribution of both the existing frame and the external dissipative bracing system.

Generally, the external bracing system is introduced mainly to control the stiffness and the damping of the system to be protected, while it contributes only marginally to the global mass. In order to give evidence of this aspect in the formulation, it is assumed that the bracing mass is null, and the total displacement vector is split into the vector , collecting the active components related to the inertia forces acting on the frame, and the vector (with ), collecting the other components related to the internal degrees of freedom, including the displacement of the bracing providing the damper deformation. The differential problem is consequently partitioned as follows:In the following, the plane problem is considered, by introducing usual simplifications for seismic frame analysis: the floors are assumed to be rigid, only the horizontal component is considered for both the ground motion and the active masses, and these latter are concentrated at the storey levels. In this case, the dimension of the vector coincides with the number of storeys, and additional degrees of freedom, collected in , are required to describe the damper deformation.

In the case of the “dissipative rocking tower,” the link between the frame and the bracing at the storey levels is rigid, so collects only the vertical displacements related to the rocking motion of the tower at the damper locations. The tower base motion described by induces an elastic deformation of the bracing and a set of reactions at the different building floor levels, described by the submatrix . Similarly, the motion of the building floor results in reactions at the base of the tower, described by the submatrix . The damper reactions due to the motion of the base of the tower are described by the matrix .

In the case of the “fixed-based structure,” collects the bracing displacements at each floor level, and the damper deformations are induced by the relative motion between the frame and the external structure. In this case, the elastic matrices and are null, whereas the elastic response of the bracing is described by . Both the motions of and produce damper forces and all the submatrices of are different from zero.

Nevertheless, both the retrofit configurations induce nonclassical damping because the distribution of the dampers results in a damping matrix which is not proportional to the global mass matrix, nor to the stiffness matrix. The rocking tower corresponds to a highly nonclassically damped system, since the viscous energy dissipation is mainly concentrated at the base of the tower. The second configuration, with the fixed-based bracing, is often characterized by a damping distribution similar to the mass distribution, and it is closer to a classically damped system.

In the following applications, an inherent damping factor equal to 0.05 is also introduced through a Rayleigh damping matrix [31] to provide a realistic description of the response without the added dampers.

2.1. Modal Properties

For the solution of the dynamic problem, corresponding to in (2), a state-space approach is convenient because it gives the opportunity to perform the complex modal analysis of the coupled system, leading to the knowledge of the modal properties in presence of nonclassical damping. For this purpose, it is useful to introduce the vector and the state vector , collecting the displacements and the velocities of the active displacements and the displacements of the internal nodes. Equation (2) can be reduced to a first-order state space form , where the ()-dimensional state matrix is expressed asAssuming a solution of the form , the eigenvalue-eigenvector pairs of , that is, , , are obtained by solving the eigenvalue problem:In general, a complex eigenvalue has the formand contains information regarding both the damping ratio and the corresponding undamped circular frequency of the th mode:It is noteworthy that the eigenvalues are () in total: of these are complex conjugates, and the remaining are real-valued and correspond to the motion of the degrees of freedom with no associated mass.

Closed-form expressions useful for the damper design can be obtained for both the external arrangements by introducing some simplifying assumptions. In the case of coupling with a fixed-based bracing, the dampers can be designed assuming the dampers constants distributed proportionally to the floor masses, that is, the damper constant at the th floor can be expressed as , where is the proportionality constant and is the floor mass. In the limit case of infinitely stiff contrasting structure, a multidegree of freedom system with mass proportional damping, which is classically damped, is obtained. Thus, the circular frequencies of the coupled system are the same as those of the undamped one, and the added damping ratio for the modes of the system iswhere and thus the values of can be calibrated to achieve a prefixed added damping ratio in correspondence of the first mode of the bare frame.

In the case of the rocking tower, a simplified expression for the damper design can be obtained by assuming infinitely rigid bracings. Under this assumption, the system acts as a single-degree of freedom, the displacement shape is linear along the building height and controlled by the base rotation , that is, , where is the vector collecting the floor heights and half of the external bracing frame width . The corresponding circular vibration frequency and added damping ratio due to the dampers located at the tower base arewhere is the viscous constant of the dampers located at the tower base. As previously, the value of can be calibrated to achieve a prefixed value of the added damping ratio for the system.

2.2. Stochastic Formulation of the Seismic Problem

The problem can be solved in the frequency-domain, rather than in the time-domain [32]. It is noteworthy that resorting to the frequency-domain has the advantage of allowing for a condensed description of the seismic problem, in terms of the active degrees of freedom only. Moreover, it permits to conveniently estimate the response to the uncertain input by exploiting already available stochastic dynamics techniques.

By denoting with and the Fourier transforms of the vectors collecting, respectively, the active degrees of freedom and internal degrees of freedom and with the transformed external scalar loading function, representative of the seismic base acceleration, the differential system of (2) can be rewritten as an algebraic system:where , for , and is the circular frequency.

Based on (9), the internal displacements can be expressed in function of asAfter substituting (10) into (9) and rearranging, the following condensed problem is obtained, where the active displacements can be directly related to the base motion through the expression:where is the transfer function vector for the problem.

It is noteworthy that both the external damping solutions can be formally expressed in terms of the condensed problem of (11). Thus, the transfer functions of the two systems can be directly compared one to each other and also to the transfer function of the bare frame in order to shed light on the effects of the different types of retrofit.

Moreover, the transfer functions can be useful to estimate the statistic of the response under a stochastic earthquake input. If both the earthquake input and the response are considered stationary, the Power Spectral Density (PSD) of the output can be expressed as follows [29]:where is the PSD of the earthquake input and is the complex conjugate of the transfer function vector.

The variance of the th floor displacement response can be obtained aswhere denotes the element of matrix in correspondence of row and column .

Finally, approximate estimates of the peak values of displacement can be obtained based on the concept of the peak factor [30]. The expected value of , evaluated according to the Davenport formula, iswhere , is the central frequency, that is, the ratio between the standard deviation of the velocity and of the displacement of the response, and is the time interval of observation.

The expected value of the maximum displacement response amplitude is thus given by . The standard deviation of the velocity response can be found asThe Fourier transform of the vector collecting any other response parameter of interest (e.g., floor accelerations, base shears) can be related to through the linear operator . Consequently, the PSD of can be obtained as follows:The corresponding peak response value for the th component of can be found by considering in (14) the relevant expression of the central frequency; that is, .

3. Case Study and Seismic Hazard

The Van Nuys building [2628] is a 7-storey 3 bay-by-8 bay cast-in-place r.c. moment resisting frame building, with nonductile column detailing, designed in 1965 in compliance to the lateral force requirements of 1964 Los Angeles City Building Code. The structural system consists of perimeter moment resisting frames and interior slab-column frames, as shown by the planar view and the transverse section (N-S direction) of Figure 2. In the same figure, the four fixed base external braced frames, connected at the floor level to the building by means of FVDs, are illustrated. The rocking braced towers are placed in the same location of the fixed-based frames and also have the same geometrical and mechanical properties.

The dynamic system is described by considering only the motion along the N-S direction. Hereinafter, the bare Van Nuys building is denoted as not-retrofitted “NR” configuration, the building coupled with the fixed base external bracing as “FB” configuration, and the building coupled with the dissipative rocking tower as “RB” configuration. The floors are assumed to be rigid in the horizontal plane and the masses are concentrated at the floor levels so that the vector of active degrees of freedom collects the seven floors motions only, for both the two retrofitting configurations. For the purpose of the analysis, a single, equivalent external structure is considered. Thus, the dimension of is seven in the case of the FB system, since it collects the horizontal displacements of the dampers at the seven floors of the external braced frame and two in the case of the RB system, since it collects the vertical displacements of the dampers located at the tower base.

The stochastic seismic input considered in all the application examples presented in this paper is a time-modulated Gaussian process whose embedded PSD function is described by the widely used Kanai-Tajimi model modified by the Clough-Penzien filter [31]; that is,in which is the amplitude of the bedrock excitation spectrum, modelled as a white noise process; and are the fundamental circular frequency and damping factor of the soil, respectively; and are the fundamental circular frequency and damping factor of the filter, respectively. The values of the soil and filter parameters used hereinafter are = 15 rad/s, = 0.6, = 1.5 rad/s, and = 0.6 [33]. Figure 3 shows the PSD function for = 1 m2/s3.

The relation between and the average peak ground acceleration (PGA) for the stochastic ground motion model employed in this study is obtained by following the procedure outlined in [34]. In particular, a set of 10000 ground motion records is generated by means of the Spectral Representation method [35], by assuming a duration = 30 s for the seismic excitation and  m2/s3. The mean value of the sample peak ground accelerations is then estimated (), and the value of corresponding to a prefixed acceleration level PGA is obtained asFor example, a value of = 0.0203 m2/s3 is obtained for PGA = 0.5, where is the gravity constant.

In order to set up a parametric analysis, a measure of the stiffness of the external system with respect to that of the existing frame is necessary. The global stiffness of the existing frame and that of the external bracings are measured by the parameters and , respectively. These are evaluated by imposing a unit horizontal displacement at the top floor and by evaluating the corresponding base reaction. For the purpose of evaluating , in the case of the rocking tower, a fixed base condition is considered to restrain the motion due to rocking. Thus, the values of are identical for the FB and RB configurations when the external steel braced frames have the same geometrical and mechanical properties. The nondimensional parameter = / is finally used to quantify the ratio of the external bracing stiffness to the existing frame stiffness, whereas the nondimensional parameter , already introduced in the previous section, is used to measure the global added damping due to the external system. In particular, for design purposes, the target (design) value of , evaluated through the expression proposed in the ASCE Standard [36], is considered:where is the dissipative work done by th device in one complete vibration cycle at the fundamental frequency of the coupled system and is the relevant maximum strain energy.

The response of the system is initially studied by considering for both the upgrading configurations a reference solution related to the parameters and = 0.3, in addition to the inherent damping of the frame equal to 0.05. Once the response of this case is discussed, a parametric analysis is carried out by considering different pairs of stiffness and damping.

3.1. Modal Properties

This section provides an insight into the modal properties of the NR frame and of the FB and RB configurations corresponding to and , evaluated based on the procedure outlined in Section 2.1. While the NR system has 7 vibration modes only, a total of 7 complex modes and 7 overdamped ones is obtained in the case of the FB system, and 7 complex modes and 2 overdamped ones in the case of the RB system.

Table 1 reports the vibration periods and damping ratios of the 7 modes of vibration of interest, which correspond to the 7 active degrees of freedom, for the different systems analyzed. The undamped vibration periods of the three configurations, obtained by neglecting the contribution of the dampers, are also evaluated to estimate the effect of the added damping separately from that of the added stiffness. It is worth observing that the FB configuration exhibits undamped periods that are the same as the NR configuration. This is because the external frame and the existing one do not interact with each other if the viscous interconnection is disregarded. On the other hand, in the case of the RB configuration, the external rocking tower interacts with the existing one through rigid connections, and this results in a reduction of the modal periods even in the undamped case (from = 1.204 s to = 1.168 s). In particular, the relative reduction of the undamped period due to the RB system is small for the first mode, around 3%, but it becomes more significant for the higher modes and it attains the values 35% and 44%, respectively, for the second and third mode.

With reference to the damped dynamic behaviour, it is observed that the first mode damped period of the FB arrangement, = 1.047 s, is 15% lower than the undamped one, = 1.204 s, and the corresponding damping ratio, = 0.33, is close to the design value 0.35 (resulting from the target design value plus the inherent damping). The higher modes are characterized by values of the undamped and damped vibration periods close to each other, and thus similar to those of the NR configurations. The values of the damping ratios are also lower than that of the fundamental mode. The RB configuration is characterized by values of the first mode damped period, = 1.029 s, and of the damping ratio, = 0.342, which are very close to those of the FB configuration. The damping ratios of the higher modes are similar to those of the FB and RB systems, whereas the damped periods are lower in the RB case.

This demonstrates again that the RB configuration induces major changes to the dynamic behaviour of the NR system, compared to the FB system, due to the different nature of the connection between the tower and the frame: viscous in the FB case and rigid in the RB one.

3.2. Frequency Response

This section analyzes the frequency response of the NR frame and of the FB and RB configurations corresponding to and = 0.3. This analysis provides a first insight into the modification of the dynamic response in terms of various EDPs of interest due to the retrofit. Figure 4 shows the absolute value of the top floor displacement and absolute acceleration Frequency Response Functions (FRFs).

With reference to the displacement, it can be seen that the response at the top of the NR frame is characterized by a very high peak at the fundamental circular frequency of vibration of the system (/ = 5.22 rad/s), as expected, whereas the influence of higher order modes is negligible. Both the retrofit systems are effective in reducing the response peak, due to the added damping. The shift of the peak is low, because the retrofit systems do not alter significantly the first mode of vibration of the existing frame. The acceleration FRFs have a very different shape compared to the displacement FRFs. This is due to the high influence of the higher order modes, which contribute significantly to the top floor acceleration response, thus resulting in multiple peaks located in correspondence of the circular frequencies of the most relevant vibration modes of the systems, that is, modes 1, 2, and 3. Again, both the retrofit systems allow reducing the peak in correspondence of the first mode of vibration. Moreover, the peaks of the FRF for the FB system are observed in correspondence of the same values of of the frame, with the exception of the first peak which is slightly shifted towards higher values in the retrofitted configuration. This is the result of the fact that the FB system does not alter significantly the dynamic response of the existing frame, by adding only damping and not stiffness. On the other hand, the RB system presents a second and third peak in correspondence of higher frequency values compared to the FB and RB systems. This is the consequence of the stiffening effect of the tower, which modifies the period and shape of the higher modes of vibration of the existing frame.

Figure 5 shows the FRF of the base shear of the frame and of the external bracings. It can be observed in Figure 5(a) that the second mode of vibration has a nonnegligible influence on the shear response of the frame, for all the analyzed arrangements. The RB system is more effective in reducing this EDP. On the other hand, the absolute values of the FRF of the external bracings base shear (Figure 5(b)) are always higher for the RB system than for the FB system. Thus, it is interesting to observe the changes of the total base shear due to the retrofit. This is plotted in Figure 6, showing that the addition of the retrofit system to the existing frame results in a reduction of the peak at the fundamental period. However, while the FB system reduces the response also at the other frequencies, the RB system amplifies the response around the value of the circular frequency of 28 rad/s (second mode).

3.3. Stochastic Seismic Response

This section reports and compares the stochastic seismic responses of the NR frame and of the FB and RB configurations corresponding to and = 0.3. In particular, Figure 7 shows and compares the PSDs of the EDPs of interest for the different systems analyzed. These PSD are the results of the convolution between the FRFs, illustrated in Figures 46, and the PSD of the input, illustrated in Figure 3. It can be observed that the PSD of the input has a peak at the period of 0.5 s. Thus, some resonance effects with the first two modes of vibration of the systems considered are expected. In particular, it is observed in Figure 7 that while the PSD of the top displacement is dominated by the first mode (Figure 7(a)), the PSDs of the other response parameters have multiple peaks. Moreover, as in the case of the FRF, the peaks are located approximately in correspondence of the same frequencies in the case of the NR and FB configurations, while in the RB case only the first peak is close to the first peak of the other systems, as a result of the changes that the RB system induces through the added stiffness on the dynamic behaviour of the existing frame. The peak force that a damper has to withstand is an important response parameter, influencing the damper cost together with the damper stroke [37]. Figure 7(f) shows that the PSD of the sum of the damper forces is largely higher for the RB case than for the FB case. This is because the strokes of the dampers in the RB frame are reduced compared to those of the dampers in the FB configuration, and thus higher forces are required to obtain the same amount of energy dissipation. Obviously, the damper forces coincide with the interaction forces between the frame and the tower in the case of the FB configuration. The cost of the retrofit depends also on these mutual exchange forces between the existing and the external structures, whose PSDs are also plotted in Figures 8(a) and 8(b). It can be seen that the exchange forces are significantly higher for the RB case than for FB case. This is because in the RB case a rigid connection rather than a viscous one is used.

The final part of the current section analyzes the peak values of the responses of interest for the different configurations. Before discussing the results, the accuracy of the method of the peak factor is evaluated comparing the average peak responses of the NR case obtained with estimated via (14) against the mean of the maxima resulting from a Monte Carlo Simulation (MCS) approach based on the frequency analysis of the system under 500 of sample seismic inputs.

Figure 9 shows the distribution of the floor displacements, interstorey drifts, absolute accelerations, and shear actions of the NR configuration according to MCS and to the peak factor method. Each response parameter is normalized to have the estimate through the peak factor method equal to one. In particular, Figure 9(a) shows the displacements distribution along the height of the building, which presents a maximum value at the top. The interstorey drifts (IDRs) distribution, reported in Figure 9(b), is not regular and the maximum is attained in correspondence of the third storey. Figure 9(c) shows the absolute accelerations at the different floors, which have S-shaped distribution, highly influenced by higher order modes, even though the maximum value is observed at the top. Finally, Figure 9(d) illustrates the shear actions resisted by the frame. Using the peak factor results in general in an overestimation of the maxima, with relative errors between 3.7% and 8.2% for all the EDPs of interest. The same technique applied to the analysis of the two retrofit configurations (FB and RB) also leads to a general underestimation of the maxima, but with a maximum relative error lower than 3%. Given the high accuracy of the obtained estimates, the response values reported hereinafter are those obtained via the peak factor method, which is computationally more efficient than MCS.

Figure 10 illustrates and compares the performances of the NR, FB, and RB configurations in terms of peak EDPs values estimated via the peak factor method. For each EDP considered, the peak values are normalized so that they are equal to unit in the NR case. This allows highlighting the benefits of the retrofit in terms of response reduction. Figure 10(a) illustrates the floor displacements distribution along the height of the building. It can be seen that the deformed shape of the existing frame remains the same after the retrofit in the FB case, whereas it is modified and linearized in the RB case. The relative reduction of the top floor displacements is nearly 61% for both the FB and RB configurations. The reduction values are similar for the two systems because the displacements are controlled by the first mode response, and the added damping ratio for this mode is nearly the same. The drift demand regularization in the case of the RB system can be better visualized in Figure 10(b), showing the interstorey drifts (IDRs) responses. The IDRs are lower in the RB system than in the FB system at the lower storeys and higher at the last two storeys.

Figure 10(c) shows the values of the floor absolute accelerations observed at the various levels of the building for the configurations investigated. The shape of the floor accelerations is not significantly modified after the retrofit, and both the FB and the RB configurations induce a reduction of the maximum absolute acceleration values with respect to the bare frame (NR). A better result in terms of maximum acceleration reduction is achieved with the FB system. This system allows a maximum reduction of the accelerations of 48% in correspondence of the last floor, while the rocking tower provides a maximum reduction of 36%. This result is of particular importance for the performance evaluation of acceleration-sensitive nonstructural components and may impair the benefits of the retrofit with the rocking system.

As already discussed for the displacements, the addition of the two external dissipative systems results in a reduction of the base shear demand in the frame; in the FB case the reduction is equal to 59%, whereas in the RB case it is equal to 61% (Figure 10(d)). In general, the reduction is different from storey to storey in the FB configuration, with higher reduction at the higher storeys, while it is nearly the same at the various storeys in the RB configuration. The RB configuration also provides a more regular distribution of the shear at the different storeys compared to the other configurations. Figure 10(e) shows the values of the shear action resisted by the external structures of the retrofit configurations, normalized with respect to the frame shear of the bare building. The RB case results in higher values at almost all the elevations, especially at lower storeys. Finally, Figure 10(f) illustrates the total storey shear. Again, the two retrofit systems exhibit similar performances in terms of base shear reduction, which is equal to 45% and 42%, respectively, in the FB and RB configurations.

Figure 11 illustrates the distribution of exchange actions for the two retrofit cases. In the FB system, where a damped connection system is used, these forces coincide with the internal axial actions in the FVDs, whose trend has already been discussed previously. In the RB configuration, the connection system is rigid, and the interaction forces are elastic and significantly higher than those of the FB case.

3.4. Parametric Study

In order to understand how the stiffness and added damping of the external FB and RB frames influence the seismic performance of the coupled system, a parametric study is carried out by varying the nondimensional parameters and representing, respectively, the external structures-to-existing frame stiffness and the added design damping ratio and by evaluating the corresponding changes in the seismic response. Three values of the parameters and are taken into account, that is, = 0.25, 0.5, 1 and = 0.1, 0.2, 0.3.

Figure 12 shows the results obtained for the two retrofit configurations in terms of the following monitored EDPs: the top floor displacement and absolute acceleration, the third floor interstorey-drift, the base shear of the frame and of the external structure, and the total base shear. The results are normalized such that the EDP values are unit in the case of the NR frame. With regard to the top floor displacement response (Figure 12(a)), it can be observed in general that both the FB and RB cases yield similar results, with a relative reduction between 38% and 61% in the FB system and a reduction between 40% and 61% in the RB system, with respect to the NR case. Higher values of the added damping result in a higher reduction of the displacement demand, as expected. Although the best performance is achieved for = 1 and = 0.3 in both the configurations, a good response reduction is obtained also for = 0.5 and = 0.3, while for = 0.25 the external structure is too flexible to resist the motion of the existing structure and activate the dampers. In fact, if is low, the external structure does not need to be very stiff to activate the dampers. On the other hand, if is high, a stiff external frame is required for the dampers to be effective.

Figure 12(b) shows the third floor interstorey drifts for the different configurations and parameter combinations. The relative reduction achieved is in the range of 38% to 60% in the FB configuration, and in the range of 45%–68% in the RB configuration. As already observed for the displacements, the best result are achieved for = 1 and = 0.3, and the case = 0.25 is characterized by a reduced efficiency with respect to the other ones.

Figure 12(c) shows the results in terms of top floor absolute acceleration. The FB case provides the best result for any combination of and . The relative reduction of this EDP for this case is between 28% and 48%, while it is between 18% and 37% in the RB case. Increasing the damping results in a reduction of the accelerations in the FB case but can increase the accelerations in the RB case for some values of and . In fact, in the RB configuration the highest value of yields also the highest acceleration demand for both = 0.25 and = 0.5, and this could affect the effectiveness of such retrofit scheme, when the protection of acceleration-sensitive components is a design objective. For = 1, similar acceleration reductions are achieved for = 0.2 and = 0.3.

Figures 12(d)12(f) describe the response in terms of frame base shear, external bracing base shear, and total base shear. Figure 12(d) shows that the relative reduction of the frame base shear is between 37% and 59% in the FB case, and between 38% and 61% in the RB case. Moreover, in the RB case the frame base shear reduction is not significantly affected by variations of , particularly for low damping values. On the other hand, the retrofit effectiveness of the FB configuration reduces significantly by considering external frames with = 0.25 rather than = 0.5 or = 1. Figure 12(e) describes the base shear resisted by the external structures. This parameter is more sensible to the added damping rather than to the stiffness ratio. Generally, higher values of and result in higher values of the bracing base shear. The values of the base shear of the external structures normalized with respect to that of the bare frame are comprised between 11% and 22% in the FB case, while they are between 23% and 39% in the RB case. Finally, from Figure 12(f) it is evident that the total base shear reduction provided by the FB and RB case is nearly the same, no matter what values of the stiffness ratio or of the added damping are considered, with a relative reduction of the shear resisted by the bare frame between 32% and 45% for the FB configuration and between 29% and 42% for the RB case, with respect to the NR frame.

Figure 13(a) illustrates the values of the maximum exchange forces between the external frames and the existing structure. In the case of the FB configuration, these correspond to the exchange forces at the top floor, whereas in the RB configuration these correspond to the exchange forces at the first floor (see Figure 11). The values for the different combinations of and are normalized so that the exchange forces in the case of = 1 and = 0.1 are equal to unit in the RB configuration, which is in general characterized by higher values compared to the FB configuration. It can be observed that, in the FB system, increasing does not affect significantly the force demand, whereas increasing yields an increase of forces. On the other hand, in the RB configuration, increasing results in an increase of forces, and increasing reduces the forces for = 0.5 and = 1. Figure 13(b) shows the maximum values of the sum of the damper forces for the two retrofit configurations. In general, these forces increase by increasing , whereas they do not increase significantly by increasing . Higher values are observed in the RB system for all the combination analyzed.

4. Conclusions

In this paper, two alternative arrangements of external passive retrofitting systems are analyzed, each one characterized by a different kinematic behaviour. The former (FB configuration) consists of an external fixed base steel braced frame connected to the existing one by means of dampers placed horizontally at the floor levels. The latter system (RB configuration) is an innovative one, based on coupling the building with a “dissipative tower,” which is a steel braced frame, hinged at the foundation level, and activating the dampers through its rocking motion. The two systems are nonclassically damped and the analysis of the performance under the uncertain earthquake input is carried out by means of a general formulation involving stochastic dynamics concepts, which allows efficiently estimating the peak values of the responses of interest and thus carrying out parametric studies for different values of the stiffness and added damping of the external structures. In particular, the FB and RB retrofit configurations are synthetically described by the parameter , measuring the ratio between the global stiffness of the external frames to that of the existing frame, and by the external frames design added damping ratio .

First, the case corresponding to = 1 and = 0.3 is analyzed in detail. The results show that the two retrofit configurations are characterized by similar performances in terms of reduction of the top displacement, interstorey drifts and total shear demand with respect to the nonretrofitted (NR) case. The RB system yields the best distribution of interstorey drifts, due to a linearization of the displacements distribution. On the other hand, this solution is characterized by higher external bracing shear actions and higher absolute floor accelerations, with respect to the FB system. The peak values of the internal actions are lower in the FB system, thanks to the viscous interconnection which does not induce significant changes in the modal shapes of the existing frame. The forces exchanged between the external bracings and the existing frame at the links placed at storey levels are significantly higher in the RB case with respect to forces observed in the interconnecting dampers in the FB case.

In the following part of the paper, a parametric analysis is carried out by considering different values of and for the two retrofitting systems and observing the changes in the response parameters usually considered in design practice. The cases corresponding to = 0.5 and = 1 provide nearly the same performance in terms of the response parameters considered, with the exception of the exchange forces in the RB configuration, which increase significantly by passing from = 0.5 to = 1. This result has significant cost implications, because lower values correspond to smaller steel profiles.

The FB system provides the best performance in terms of reduction of absolute accelerations of the top floor compared to the RB system for all the nondimensional parameter combinations. Moreover, the top floor absolute acceleration generally increases by increasing the added damping in the RB case. The total base shear in the two retrofit configurations is nearly the same for all the values of and considered. The existing frame base shear and the external bracings shear, respectively, decrease and increase by increasing , while they are less sensitive to variations of . Finally the RB configuration provides always higher values of both exchange forces and axial actions in the FVDs, with respect to the FB case, for all the values of and considered.

Conflicts of Interest

The authors declare that there are no conflicts of interest regarding the publication of this paper.

Acknowledgments

The study reported in this paper was partially supported by the Italian Department of Civil Protection within the Reluis-DPC Projects 2017. The authors gratefully acknowledge this financial support.