Table of Contents Author Guidelines Submit a Manuscript
Shock and Vibration
Volume 2018 (2018), Article ID 5630746, 16 pages
https://doi.org/10.1155/2018/5630746
Research Article

Development of a Multiaction Hybrid Damper for Passive Energy Dissipation

1Department of Architectural Engineering, Dankook University, Yongin, Republic of Korea
2Heun Deul Lim Corporation, Seongnam, Republic of Korea

Correspondence should be addressed to Sang-Hyun Lee

Received 28 July 2017; Revised 11 December 2017; Accepted 2 January 2018; Published 31 January 2018

Academic Editor: Abdul Qadir Bhatti

Copyright © 2018 Ji-Eun Roh et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. D. M. Bergman and S. C. Goel, “Evaluation of cyclic testing of steel plate devices for added damping and stiffness,” Report no. UMCE87-10. Ann Arbor (MI,USA): The University of Michigan, 1987.
  2. K.-C. Tsai, H.-W. Chen, C.-P. Hong, and Y.-F. Su, “Design of steel triangular plate energy absorbers for seismic-resistant construction,” Earthquake Spectra, vol. 9, no. 3, pp. 505–528, 1993. View at Publisher · View at Google Scholar · View at Scopus
  3. T. Kobori, Y. Miura, E. Fukusawa, T. Yamada, T. Arita, and Y. Takenake, “Development and application of hysteresis steel dampers,” in Proceedings of the 11th World Conference on Earthquake Engineering, pp. 2341–2346, 1992.
  4. P. W. Clark, I. D. Aiken, F. Tajirian, K. Kasai, E. Ko, and I. Kimura, “Design procedures for buildings incorporating hysteretic damping devices,” In: Proc. int. post-SmiRT conf. seminar on seismic isolation. Passive energy dissipation and active control of vibrations of structures, 1999.
  5. A. S. Pall and C. Marsh, “Response of friction damped braced frames,” Journal of the Structural Division, vol. 108, no. 6, pp. 1313–1323, 1982. View at Google Scholar · View at Scopus
  6. I. H. Mualla, Experimental and computational evaluation of a novel friction damper device [Ph.D. thesis], Department of Structural Engineering and Materials, Technical University of Denmark, 2000.
  7. T. F. FitzGerald, T. Anagnos, M. Goodson, and T. Zsutty, “Slotted bolted connections in aseismic design for concentrically braced connections,” Earthquake Spectra, vol. 5, no. 2, pp. 383–391, 1989. View at Publisher · View at Google Scholar · View at Scopus
  8. A. Filiatrault and S. Cherry, “Seismic design spectra for friction‐damped structures,” Journal of Structural Engineering, vol. 116, no. 5, pp. 1334–1355, 1990. View at Publisher · View at Google Scholar
  9. Y. Fu and S. Cherry, “Design of friction damped structures using lateral force procedure,” Earthquake Engineering & Structural Dynamics, vol. 29, no. 7, pp. 989–1010, 2000. View at Publisher · View at Google Scholar · View at Scopus
  10. S.-H. Lee, J.-H. Park, S.-K. Lee, and K.-W. Min, “Allocation and slip load of friction dampers for a seismically excited building structure based on storey shear force distribution,” Engineering Structures, vol. 30, no. 4, pp. 930–940, 2008. View at Publisher · View at Google Scholar · View at Scopus
  11. W. H. Robinson, “Lead‐rubber hysteretic bearings suitable for protecting structures during earthquakes,” Earthquake Engineering & Structural Dynamics, vol. 10, no. 4, pp. 593–604, 1982. View at Publisher · View at Google Scholar · View at Scopus
  12. J. D. Marshall and F. A. Charney, “A hybrid passive control device for steel structures, I: Development and analysis,” Journal of Constructional Steel Research, vol. 66, no. 10, pp. 1278–1286, 2010. View at Publisher · View at Google Scholar · View at Scopus
  13. C. Christopoulos and M. Montgomery, “Viscoelastic coupling dampers (VCDs) for enhanced wind and seismic performance of high-rise buildings,” Earthquake Engineering & Structural Dynamics, vol. 42, no. 15, pp. 2217–2233, 2013. View at Publisher · View at Google Scholar · View at Scopus
  14. C.-H. Lee, J. Kim, D.-H. Kim, J. Ryu, and Y. K. Ju, “Numerical and experimental analysis of combined behavior of shear-type friction damper and non-uniform strip damper for multi-level seismic protection,” Engineering Structures, vol. 114, pp. 75–92, 2016. View at Publisher · View at Google Scholar · View at Scopus
  15. KBC2016, Korean Building Code, 2016, Korean Architectural Institute.
  16. Midas Gen Analysis Manual. 2016, Midas IT.
  17. J. C. Wu, J. N. Yang, and W. E. Schmitendorf, “Reduced-order H∞ and LQR control for wind-excited tall buildings,” Engineering Structures, vol. 20, no. 3, pp. 222–236, 1998. View at Publisher · View at Google Scholar · View at Scopus
  18. Building Seismic Safety Council. NEHRP guidelines for the seismic rehabilitation of building. FEMA 273. Washington, DC: Building Seismic Safety Council, 1997.
  19. Perform-3D User Guide: Nonlinear Analysis and Performance Assessment for 3D Structures. 2006, Computers & Structures Inc.