Research Article
Bearing Diagnostics of Hydro Power Plants Using Wavelet Packet Transform and a Hidden Markov Model with Orbit Curves
Table 2
DC filtering techniques result.
| Acquisition | Mean value | FIR filter | Difference |
| 16/04/2017 | 1089.76 [μm] | 1087.34 [μm] | 0.22 [%] | 02/05/2017 | 1023.05 [μm] | 1022.54 [μm] | 0.05 [%] | 20/03/2017 | 1018.53 [μm] | 1018.09 [μm] | 0.04 [%] | 23/05/2017 | 1035.73 [μm] | 1036.67 [μm] | 0.09 [%] | 09/09/2016 | 1063.90 [μm] | 1063.50 [μm] | 0.04 [%] | 17/04/2017 | 1064.40 [μm] | 1063.52 [μm] | 0.08 [%] |
|
|