Bearing Diagnostics of Hydro Power Plants Using Wavelet Packet Transform and a Hidden Markov Model with Orbit Curves
Table 3
SNR comparison.
Harmonic
Frequency [Hz]
SNR before
SNR after
0
0
37.39
317.62
1
3.33
35.68
304.38
3
10
25.99
205.45
6
20
17.77
191.3
8
26.66
15.16
132.9