Research Article

Crack Detection of Reinforced Concrete Structures Based on BOFDA and FBG Sensors

Table 2

Error statistic.

Theoretical position (m)Measured position (m)Relative error (%)

7.557.550
11.2511.905.8
14.9515.554.0
18.6519.65.1