Research Article

Fault Diagnosis of Bearings with Adjusted Vibration Spectrum Images

Table 6

The classification accuracy for ball fault severity detection.

DatasetnTesting accuracy (%)
Load 0Load 1Load 2Load 3

E1197.8395.5097.7289.92
310099.2898.6596.58
510099.6399.3897.47
1010010099.5898.20

E2199.6510099.9799.95
3100100100100
5100100100100
10100100100100

E3169.4099.15100100
374.2599.70100100
576.5099.78100100
1076.83100100100

E4176.8398.58100100
374.4098.88100100
574.8098.25100100
1074.9797.33100100

n is the training samples per class under each of the specified load conditions.