Comparisons for single-fault severity detection between current work and some published work.

ObjectiveMethod in refs.Training dataTesting dataClassification accuracy (%)

IF severity detectionSSL in [16]Load 0 (40)Load 0–3 (1560)100
Load 1 (40)Load 0–3 (1560)100
Load 2 (40)Load 0–3 (1560)100
Load 3 (40)Load 0–3 (1560)100
Dataset D1 in present workLoad 0 (40)Load 0–3 (760)100
Dataset D2 in present workLoad 1 (20)Load 0–3 (780)100
Dataset D3 in present workLoad 2 (40)Load 0–3 (760)100
Dataset D4 in present workLoad 3 (20)Load 0–3 (780)100
SVMs and fractal dimension in [17]Load 3 (472)Load 3 (472)100
Dataset D4 in present workLoad 3 (12)Load 3 (188)100

BF severity detectionSSL in [16]Load 0 (40)Load 0–3 (1560)85.26
Load 1 (40)Load 0–3 (1560)96.19
Load 2 (40)Load 0–3 (1560)96.59
Load 3 (40)Load 0–3 (1560)79.49
SVMs and fractal dimension in [17]Load 3 (472)Load 3 (472)96.31
Dataset E1 in present workLoad 0 (40)Load 0–3 (760)99.42
Dataset E2 in present workLoad 1 (12)Load 0–3 (788)100
Dataset E3 in present workLoad 2 (20)Load 0–3 (780)91.49
Dataset E4 in present workLoad 3 (20)Load 0–3 (780)90.53

OF severity detectionSSL in [16]Load 0 (40)Load 0–3 (1560)100
Load 1 (40)Load 0–3 (1560)100
Load 2 (40)Load 0–3 (1560)100
Load 3 (40)Load 0–3 (1560)100
SVMs and fractal dimension in [17]Load 3 (472)Load 3 (472)99.89
Dataset F1 in present workLoad 0 (12)Load 0–3 (788)100
Dataset F2 in present workLoad 1 (12)Load 0–3 (788)100
Dataset F3 in present workLoad 2 (12)Load 0–3 (788)100
Dataset F4 in present workLoad 3 (12)Load 0–3 (788)100
Dataset F4 in present workLoad 3 (12)Load 3 (188)100

The classification accuracy is determined by no. of successfully classified samples/No. of total testing samples 100% under specified load condition.