Research Article

A Vibration-Isolating Blast Technique with Shock-Reflection Device for Dam Foundation Excavation in Complicated Geological Conditions

Table 1

The intensity of transmission and reflection wave at the interface.

Sonic impedance (kg/m3·m/s) Interface BInterface C
Explosion productsConcreteCoarse sandRTRT

3.60×1061.85×1074.25×1060.67I1.67I-0.63I0.37I