Research Article

A Vibration-Isolating Blast Technique with Shock-Reflection Device for Dam Foundation Excavation in Complicated Geological Conditions

Table 3

Summary of PPV and vibration reduction factor.

Location
of detector
Top ignition (cm/s)Bottom ignition (cm/s)
B (Without)A (With)D (Without)C (With)

1# (1.0m)32.5018.3743.5%33.3514.5156.5%

2# (1.5m)34.4019.2144.2%21.4711.0948.3%

3# (2.0m)27.5519.3329.8%14.077.9243.7%