Research Article

Full-Scale Tests for Assessing Blasting-Induced Vibration and Noise

Table 4

Maximum charge per delay with vibration value and distance (unit: kg/delay).
(a) V = 0.2cm/sec

EquationConfidence levelDistance (m)
102030405060708090100110

SRE50%0.070.300.671.191.862.683.654.776.047.469.02
95%0.030.120.260.460.721.041.411.842.332.883.48

CRE50%0.010.100.350.831.622.794.436.629.4212.9217.20
95%0.000.020.070.180.340.590.941.412.002.743.65

(b) V = 0.3cm/sec

EquationConfidence levelDistance (m)
102030405060708090100110

SRE50%0.130.501.132.003.134.516.148.0110.1412.5215.15
95%0.050.190.430.771.211.742.373.093.914.835.85

CRE50%0.030.220.751.793.496.049.5914.3120.3827.9637.21
95%0.010.050.160.380.741.282.043.044.335.947.90

(c) V = 0.5cm/sec

EquationConfidence levelDistance (m)
102030405060708090100110

SRE50%0.240.962.163.856.018.6611.7915.3919.4824.0529.11
95%0.090.370.841.482.323.344.555.947.529.2811.23

CRE50%0.070.592.004.739.2415.9725.3637.8553.8973.9298.39
95%0.020.130.421.001.963.395.398.0411.4515.7020.90