Research Article
Feature Extraction Based on Adaptive Multiwavelets and LTSA for Rotating Machinery Fault Diagnosis
Table 6
Values of the SDI and free parameters a, b, c, d, and f corresponding to the optimal multiwavelets for hydroelectric generator unit experiment.
| Scale | A01 | A02 | D01 | D02 | D11 | D12 | D21 | D22 |
| SDI | 7.56 | 7.12 | 7.24 | 8.91 | 8.43 | 16.66 | 10.72 | 11.45 | a | −2.67 | 4.32 | −1.09 | 4.52 | −9.48 | −6.42 | −6.80 | 3.03 | b | 5.13 | −7.51 | −8.82 | −0.17 | −0.20 | −6.29 | −7.62 | 1.18 | c | −5.50 | −1.29 | −7.95 | 5.09 | −8.94 | −7.18 | −0.16 | 9.60 | d | −3.32 | −9.87 | −7.12 | 0.15 | 0.01 | 8.67 | 2.13 | 0.78 | f | −1.39 | −7.54 | 1.81 | 9.34 | 1.45 | 2.67 | 0.75 | −0.00 |
|
|