Research Article

Research on Pipeline Damage Imaging Technology Based on Ultrasonic Guided Waves

Table 2

Guide wave propagation distances between the signal receiving point and defect reflection point.

NumberFirst signal time ()End echo signal time ()Transmission speed ()Damage signal time ()Time delay ()Propagation distance ()

S195.301127.855229.77362.35267.05698.61
S295.351127.805230.28363.00267.65701.88
S395.451127.855230.53365.80270.35716.07
S495.401127.705231.04370.30274.90740.01
S595.351127.865229.98376.45281.10772.15
S695.301127.705230.53370.25274.95740.13
S795.451127.855230.53365.75270.30715.81
S895.501127.805231.04363.10267.60701.83