Research Article

Research on Pipeline Damage Imaging Technology Based on Ultrasonic Guided Waves

Table 5

Double-defect guided signal data.

NumberFirst signal reception time ()End echo signal time ()Wave speed ()Near-end defect echo time ()Proximal defect signal propagation distance ()Remote defect echo time ()Remote defect signal propagation distance ()

S195.401129.955219.66247.55795.737362.401396.397
S295.401128.055229.26248.95803.059363.101400.058
S395.401127.805230.53253.45826.594365.751413.917
S495.401127.855230.28259.70864.511370.251437.452
S595.351127.755230.53270.20914.457376.851472.231
S695.401127.805230.53259.80864.249370.351437.975
S795.401128.055229.26253.45826.332365.751413.917
S895.351128.005229.26248.95802.797363.001399.796