The parameters optimization results of the IDVA
| εb | Optimized ζa | Optimized σa | Optimized σb | ωi |
| 0.01 | 0.05 | 0.98 | 1 | 2.743 | 0.02 | 0.04 | 0.99 | 0.98 | 2.756 | 0.03 | 0.05 | 0.98 | 0.95 | 2.759 | 0.04 | 0.05 | 0.98 | 0.94 | 2.750 | 0.05 | 0.05 | 0.98 | 0.92 | 2.753 | 0.06 | 0.05 | 0.98 | 0.91 | 2.745 | 0.07 | 0.05 | 0.98 | 0.90 | 2.739 | 0.08 | 0.06 | 0.97 | 0.85 | 2.735 | 0.09 | 0.05 | 0.98 | 0.88 | 2.731 | 0.10 | 0.05 | 0.98 | 0.87 | 2.728 |
|
|