Research Article

Thermomechanical Coupling Analysis and Optimization of Metallic Thermal Protection System

Table 2

Comparison between experiment and numerical analysis for the honeycomb cell.

Time51015202530

Experiment (°C)30.358.8108.0176.0258.7352.1
FE Analysis (°C)28.5855.18107.20188.06274.53369.76
Error (%)5.576.160.746.856.125.01