Tab 2
/
Research Article
Thermomechanical Coupling Analysis and Optimization of Metallic Thermal Protection System
Table 2
Comparison between experiment and numerical analysis for the honeycomb cell.
Time
5
10
15
20
25
30
Experiment (°C)
30.3
58.8
108.0
176.0
258.7
352.1
FE Analysis (°C)
28.58
55.18
107.20
188.06
274.53
369.76
Error (%)
5.57
6.16
0.74
6.85
6.12
5.01