Research Article

Shaking Table Array Tests of an Ultra-High-Voltage Cup-Type Transmission Tower-Line System

Table 4

Comparison of the basic dynamic characteristics of the middle towers of the four models.

ModelFrequencyDamping ratio
f1 (Hz)f2 (Hz)C1 (%)C2 (%)

Single-tower model7.2027.5680.922.40
Single tower with suspended lumped masses6.8367.2631.061.18
Three-tower-two-line model7.1437.2652.992.58
Five-tower-four-line model7.1437.2652.381.65