Table 8

Transverse peak displacement responses of the middle towers of the four models.

Test seriesSingle-tower model (mm)Single-tower model with suspended lumped masses (mm)Three-tower-two-line model (mm)Five-tower-four-line model (mm)

0.07 g artificial wave2.1341.6873.1261.848
0.07 g El Centro wave0.8110.5430.7200.736
0.07 g Taft wave1.1270.8830.8240.897
0.07 g average1.3571.0381.5571.161
0.21 g artificial wave7.2585.2239.6636.032
0.21 g El Centro wave2.1482.4472.5142.089
0.21 g Taft wave3.9622.2332.9763.130
0.21 g average4.4563.3015.0513.750
0.63 g artificial wave21.15216.14126.78516.364
0.63 g El Centro wave7.5137.2508.1626.549
0.63 g Taft wave12.2047.0457.7688.783
0.63 g average13.62310.14614.23810.565