Tab 4
/
Research Article
Automatic Evaluation of Internal Combustion Engine Noise Based on an Auditory Model
Table 4
Comparison of auditory spectrum and time-domain input test results.
Model
Input
Training accuracy (%)
Test accuracy (%)
CNN
Auditory spectrum
97.31
95.28
CNN
Time domain
92.79
91.75