Test data.

Position of hoistLength of counterweight tail rope (m)Measured value of sensor nos. 1, 2, 3, and 4 (kN)Sum tension of four wire ropes (kN)Total mass of hoist (t)Mass of counterweight tail rope (t)
BeforeAfterBeforeAfter

Pithead62034.7, 35.1, 35.8, 36.237.8, 39.6, 39.5, 38.7141.8155.615.8887.688
Middle of the pit30029.6, 26.8, 28.3, 26.529.7, 30.6, 29.3, 29.1111.2118.711.923.72