Research Article
Effect of Structure Parameters on Polycal Wire Rope Isolator Stiffness-Damping Characteristics
Table 3
The mechanical parameters of single strands with different diameter ratios.
| FEM results of single strand | | 1.1 | 1.2 | 1.3 | 1.4 | 1.5 |
| Center strand | (GPa) | 70.10 | 63.25 | 60.58 | 59.52 | 57.29 | (GPa) | 11.52 | 12.38 | 13.48 | 14.80 | 15.94 | (MPa) | 17.50 | 16.21 | 16.16 | 16.54 | 16.33 |
| Lay strand | (GPa) | 77.61 | 69.16 | 67.05 | 65.73 | 61.94 | (GPa) | 11.80 | 12.45 | 13.52 | 14.87 | 16.00 | (MPa) | 17.78 | 16.41 | 16.15 | 16.93 | 16.77 |
|
|