Research Article

Wind Load and Structural Parameters Estimation from Incomplete Measurements

Table 8

Estimation of structural parameters under different numbers of measurements.

Structural parameterNine measurementsEight measurementsSeven measurementsSix measurementsFive measurementsFour measurements
Value (×108)Error (%)Value (×108)Error (%)Value (×108)Error (%)Value (×108)Error (%)Value (×108)Error (%)Value (×108)Error (%)

k12.522.812.373.382.553.972.354.122.616.522.689.51
k22.392.562.522.882.373.442.554.022.606.282.689.48
k32.402.032.373.122.354.152.344.312.585.452.219.62
k42.401.972.533.242.543.842.305.982.616.442.229.26
k52.512.352.533.442.353.962.595.652.286.742.699.64
k62.512.262.382.762.353.992.575.072.296.392.7010.08
k72.382.862.373.422.554.082.574.942.306.272.689.25
k82.392.282.522.982.554.192.325.432.626.742.7110.46
k92.491.502.512.492.533.372.554.252.296.732.679.18
k102.502.122.533.402.344.302.585.432.296.622.699.61
Α × 1080.5773.630.5813.710.5814.250.6129.830.5926.270.6068.71
β × 1080.003420.760.00352.80.003482.240.003585.330.003811.760.0038413.01